Energy & Power Template

Geothermal Energy Daily Report Template

231+ fields across 11+ sections. BLM 43 CFR 3200, IADC DDR, OSHA 1926 compliant. Preview every field below — subscribe to download.

PLAN OF DAY
POD Daily Report Template

Geothermal Energy

Construction Daily Report — 1 industry sections + 8 common sections

0
Total Fields
231
Industry Fields
98
Common Fields
52
KPI Mapped
BLM 43 CFR 3200IADC DDROSHA 1926State Geothermal Permits
© 2026 Plan of Day, Inc. All rights reserved.planofday.com

Common Sections (98 fields shared across all industries)

Geothermal Energy — Industry Sections (231 fields)

Field NameTypeUnitRequiredPOD KPI
1Report DatedateRequired
2Report NumberintegerRequired
3Project NamestringRequired
4Project Number / Contract #stringRequired
5Well Pad / Well IDstringRequired
6Rig Name / NumberstringRequired
7Operator / OwnerstringBest Practice
8Drilling ContractorstringRequired
9Superintendent / Tool PusherstringRequired
10Weather — Conditionenum (Clear, Partly Cloudy, Overcast, Rain, Snow, Wind)Required
11Weather — Temperature Highnumber°FRequired
12Weather — Temperature Lownumber°FRequired
13Weather — Wind SpeednumbermphBest Practice
14Weather — Wind GustsnumbermphBest Practice
15Elevation (Well Pad)numberft MSLRequired
16Geothermal Resource Area (GRA)stringBest Practice
17Shiftenum (Day, Night, 24hr)Required
18Hours Worked This ShiftnumberhrsRequired
19Days Since Last LTIintegerdaysRequired
20Overall Well Statusenum (Drilling, Casing, Cementing, Completion, Testing, Standby, Rig Move)Required
21Depth — Start of Day (Measured Depth)numberftRequired
22Depth — End of Day (Measured Depth)numberftRequired
23Depth — True Vertical Depth (TVD)numberftRequired
24Target Total Depth (TD)numberftRequired
25Footage Drilled TodaynumberftRequired
26Cumulative Footage DrillednumberftRequired
27Rate of Penetration — Averagenumberft/hrRequired
28Rate of Penetration — Peaknumberft/hrBest Practice
29Rotating HoursnumberhrsRequired
30Circulating HoursnumberhrsRequired
31Trip TimenumberhrsBest Practice
32Non-Productive Time (NPT)numberhrsRequired
33NPT Reason Codeenum (Mechanical, Weather, Waiting, Fishing, Lost Circ, Other)Required
34NPT DescriptiontextBest Practice
35Hole SizenumberinchesRequired
36Hole Conditionenum (Good, Tight, Sloughing, Wash Out, Lost Returns)Required
37Bit NumberintegerRequired
38Bit Typeenum (Tri-cone, PDC, Impreg, Coring)Required
39Bit SizenumberinchesRequired
40IADC CodestringBest Practice
41Depth InnumberftRequired
42Depth OutnumberftRequired
43Footage on BitnumberftRequired
44Hours on BitnumberhrsRequired
45Bit Dull Grade (In)stringBest Practice
46Bit Dull Grade (Out)stringRequired
47Mud Typeenum (Water-Based, Gel/Polymer, Aerated, Air/Mist, Foam)Required
48Mud Weightnumberlb/gal (ppg)Required
49Funnel Viscositynumbersec/qtRequired
50Plastic Viscosity (PV)numbercPBest Practice
51Yield Point (YP)numberlb/100ft²Best Practice
52pHnumberRequired
53ChloridesnumberppmRequired
54Fluid Loss (API)numbermL/30minRequired
55Total Solidsnumber% by volBest Practice
56Sand Contentnumber% by volBest Practice
57Mud Volume — Surface SystemnumberbblRequired
58Mud Volume — HolenumberbblRequired
59Mud Material Used TodaytextBest Practice
60Survey Depth (MD)numberftRequired
61InclinationnumberdegreesRequired
62AzimuthnumberdegreesRequired
63Dog Leg Severity (DLS)number°/100ftBest Practice
64Survey Toolenum (Gyro, MWD, Single-Shot)Best Practice
65Casing Size (OD)numberinchesRequired
66Casing Weightnumberlb/ftRequired
67Casing GradestringRequired
68Casing Connection TypestringBest Practice
69Casing Depth SetnumberftRequired
70Joints Run TodayintegerRequired
71Cumulative Joints RunintegerRequired
72Casing Running TimenumberhrsBest Practice
73Casing Tally (Total Length)numberftRequired
74Centralizers InstalledintegerBest Practice
75Float EquipmentstringBest Practice
76Cement Slurry Typeenum (Neat, Thermal, Silica-Flour, Lightweight, Foamed)Required
77Cement Slurry Volume — LeadnumberbblRequired
78Cement Slurry Volume — TailnumberbblBest Practice
79Cement Slurry Density — Leadnumberlb/galRequired
80Cement Slurry Density — Tailnumberlb/galBest Practice
81Displacement VolumenumberbblBest Practice
82Cement Returnsenum (Full, Partial, None)Required
83WOC (Wait on Cement) TimenumberhrsRequired
84CBL/VDL Log RunbooleanBest Practice
85CBL Bond Qualityenum (Good, Fair, Poor, No Bond)Best Practice
86Wellhead Type / Pressure RatingstringRequired
87Wellhead Installation Statusenum (Not Started, In Progress, Complete, Tested)Required
88Pressure Test ResultnumberpsiRequired
89Pressure Test DurationnumberminBest Practice
90Pressure Test Pass/Failenum (Pass, Fail)Required
91Bottom Hole Temperature (BHT)number°FRequired
92BHT Measurement DepthnumberftRequired
93BHT Measurement Typeenum (Static, Circulating, Horner-Corrected)Best Practice
94Bottom Hole Pressure (BHP)numberpsiRequired
95BHP Measurement Typeenum (Static, Flowing, Shut-In)Best Practice
96Flow Test — Flow Ratenumberklb/hrRequired
97Flow Test — Steam Fractionnumber%Best Practice
98Flow Test — Wellhead PressurenumberpsigRequired
99Flow Test — EnthalpynumberBTU/lbRequired
100Flow Test — DurationnumberhrsBest Practice
101Lost Circulation Zone — DepthnumberftRequired
102Lost Circulation — Severityenum (Seepage <10 bbl/hr, Partial 10-50 bbl/hr, Severe 50-200 bbl/hr, Total >200 bbl/hr)Required
103Lost Circulation — Fluid LostnumberbblRequired
104Lost Circulation — LCM Type UsedstringBest Practice
105Lost Circulation — LCM VolumenumberbblBest Practice
106Formation LithologytextBest Practice
107Core Samples TakenbooleanBest Practice
108Core Recoverynumber%Best Practice
109Brine Silica ConcentrationnumberppmRequired
110Brine pHnumberRequired
111Brine Total Dissolved Solids (TDS)numbermg/LRequired
112H2S Concentration — WellborenumberppmRequired
113CO2 Concentration — Non-condensable gasnumber%Best Practice
114ArsenicnumberppbBest Practice
115BoronnumberppmBest Practice
116MercurynumberppbBest Practice
117Thermal Gradientnumber°F/100ftRequired
118Reservoir Temperature (Estimated)number°FRequired
119Scaling Potential Assessmentenum (Low, Moderate, High, Severe)Required
120Scale Inhibitor AppliedbooleanBest Practice
121Scale Inhibitor TypestringBest Practice
122Scale Inhibitor Dosage RatenumberppmBest Practice
123Corrosion Rate — Coupon Readingnumbermpy (mils/yr)Best Practice
124Reinjection Well Statusenum (Active, Standby, Offline, N/A)Best Practice
125Reinjection Ratenumberklb/hrBest Practice
126Induced Seismicity — Events DetectedintegercountBest Practice
127Induced Seismicity — Max MagnitudenumberM (Richter)Best Practice
128Plant Typeenum (Flash, Binary/ORC, Dry Steam, Combined Flash-Binary, Hybrid)Required
129ORC Turbine — Model / ManufacturerstringBest Practice
130ORC Turbine — Installation Statusenum (Foundation, Set, Aligned, Piped, Wired, Tested, Complete)Required
131Heat Exchanger — Typeenum (Shell & Tube, Plate, Air-Cooled)Required
132Heat Exchanger — Installation Statusenum (Foundation, Set, Piped, Tested, Complete)Required
133Cooling Tower — Typeenum (Wet Mechanical Draft, Dry Air-Cooled, Hybrid)Best Practice
134Cooling Tower — Installation Statusenum (Foundation, Steel, Fill, Mechanical, Testing, Complete)Required
135Generator — Nameplate CapacitynumberMWRequired
136Generator — Installation Statusenum (Foundation, Set, Aligned, Wired, Tested, Complete)Required
137Working Fluid Chargeenum (Not Started, Partial, Complete, N/A)Best Practice
138Transformer — Installation Statusenum (Pad, Set, Wired, Tested, Complete)Best Practice
139Interconnection / Switchyard Statusenum (Not Started, In Progress, Testing, Energized, Complete)Best Practice
140Control Building / DCS Statusenum (Structure, Equipment, Wiring, Commissioning, Complete)Best Practice
141Structural Steel — Tonnage Erected TodaynumbertonsBest Practice
142Concrete — Volume Placed Today (Plant)numberCYBest Practice
143Steam Gathering — Pipe SizenumberinchesRequired
144Steam Gathering — Materialenum (Carbon Steel, Alloy Steel, Stainless, FRP)Required
145Steam Gathering — Footage Installed TodaynumberLFRequired
146Steam Gathering — Cumulative FootagenumberLFRequired
147Steam Gathering — Planned Total FootagenumberLFRequired
148Brine Line — Pipe SizenumberinchesBest Practice
149Brine Line — Materialenum (Carbon Steel, Duplex SS, Lined CS, HDPE)Best Practice
150Brine Line — Footage Installed TodaynumberLFBest Practice
151Condensate Return — Footage TodaynumberLFBest Practice
152Welds Completed TodayintegerRequired
153Welds — NDE Tested TodayintegerRequired
154Welds — NDE Pass Ratenumber%Required
155Welds — Repair Ratenumber%Best Practice
156Pipe Supports Installed TodayintegerBest Practice
157Expansion Joints / Bellows InstalledintegerBest Practice
158Insulation — LF Applied TodaynumberLFBest Practice
159Hydrostatic Test Status (by system)enum (Not Started, In Progress, Hold, Pass, Fail)Best Practice
160H2S Area Monitor — TWA (8hr)numberppmRequired
161H2S Area Monitor — STEL (15min)numberppmRequired
162H2S Area Monitor — Ceiling / PeaknumberppmRequired
163H2S Personal Monitor AlarmsintegercountRequired
164H2S Alarm Response ActionstextBest Practice
165SCBA Sets AvailableintegercountRequired
166Wind Socks / H2S Indicators VisiblebooleanRequired
167Thermal Burn Risk Assessmentenum (Low, Medium, High, Extreme)Required
168High-Temp PPE Compliancenumber%Required
169Confined Space Entries TodayintegercountRequired
170Hot Work Permits ActiveintegercountRequired
171Toolbox Talk — TopicstringRequired
172Toolbox Talk — AttendeesintegercountRequired
173Near Misses ReportedintegercountRequired
174First Aid CasesintegercountRequired
175Recordable InjuriesintegercountRequired
176Lost Time InjuriesintegercountRequired
177Emergency Muster DrillbooleanBest Practice
178Safety Observations SubmittedintegercountBest Practice
179JSA / JHA Reviews CompletedintegercountBest Practice
180Noise Level — At SourcenumberdBARequired
181Noise Level — At Property LinenumberdBABest Practice
182H2S Emissions — Stack / Ventnumberlb/hrRequired
183Particulate Emissions — Visibleenum (None, Light, Moderate, Heavy)Best Practice
184Produced Fluid Containment — Statusenum (Intact, Minor Leak, Spill, N/A)Required
185Spill EventbooleanRequired
186Spill VolumenumbergalRequired (if spill)
187Spill — Material ReleasedstringRequired (if spill)
188Spill — Cleanup Statusenum (Active, Contained, Remediated, Reported)Required (if spill)
189Stormwater BMP Statusenum (Good, Needs Maintenance, Damaged, N/A)Best Practice
190Waste Generated — Drill CuttingsnumberCYBest Practice
191Waste Generated — Used MudnumberbblBest Practice
192Waste Manifests GeneratedintegercountBest Practice
193BLM Form 3260-4 FiledbooleanRequired
194Cultural / Archaeological Monitor On-SitebooleanBest Practice
195Rig Type / HP RatingstringRequired
196Rig Statusenum (Drilling, Tripping, Casing, Cementing, Logging, Standby, Rig Move, Repair)Required
197Mud Pumps — # Active / # AvailablestringRequired
198Mud Pump PressurenumberpsiBest Practice
199Air Compressors — Statusenum (Running, Standby, Down)Best Practice
200Rotating Head / Diverter — Statusenum (Installed, Functional, Repair Needed)Best Practice
201BOP — Type / RatingstringRequired
202BOP — Last Test DatedateRequired
203BOP — Test PressurenumberpsiRequired
204Support Equipment — CranesintegercountBest Practice
205Support Equipment — ForkliftsintegercountBest Practice
206Support Equipment — Welding MachinesintegercountBest Practice
207Support Equipment — Light TowersintegercountBest Practice
208Crew Count — Company MenintegercountRequired
209Crew Count — Drilling CrewintegercountRequired
210Crew Count — Directional DrillerintegercountBest Practice
211Crew Count — Mud EngineerintegercountBest Practice
212Crew Count — Cement CrewintegercountBest Practice
213Crew Count — Logging CrewintegercountBest Practice
214Crew Count — Pipefitters / WeldersintegercountBest Practice
215Crew Count — ElectriciansintegercountBest Practice
216Crew Count — LaborersintegercountBest Practice
217Crew Count — HSE PersonnelintegercountRequired
218Total Personnel On SiteintegercountRequired
219Subcontractors — Company NamestextBest Practice
220Subcontractors — Headcount by CompanytextBest Practice
221BLM Geothermal Lease NumberstringRequired
222BLM Sundry Notice (Form 3260-3) Statusenum (Approved, Pending, Amendment Needed)Best Practice
223State Drilling Permit #stringRequired
224State Permit Conditions — Complianceenum (In Compliance, Deviation, Violation)Required
225Air Quality Permit #stringBest Practice
226OSHA 300 Log — UpdatedbooleanRequired
227Water Discharge Permit (NPDES)stringBest Practice
228UIC Permit (Underground Injection)stringRequired
229Inspection by Regulatory AgencybooleanBest Practice
230Inspector Name / AgencystringBest Practice (if yes)
231Inspection Findings / Action ItemstextBest Practice (if yes)
Subscribe to download this template

5 Role Variants Available

GC / EPC
200-300
fields · Complete master report
Owner / Client
40-60
fields · Executive summary
Subcontractor
50-80
fields · Trade-specific
Safety / HSE
60-80
fields · Deep safety detail
Foreman / Field
30-50
fields · Quick field entry

Frequently Asked Questions

Last updated: March 2026