Free Confined Space Entry Permit Template
Manage confined space entries with atmospheric monitoring, rescue planning, entrant/attendant logs, and OSHA 1926 Subpart AA compliance.
What's Included
This template includes 3 organized sections ready for your project.
Entry Permit
Atmospheric Log
Rescue Plan
Key Features
Everything you need to manage Confined Space Entry Permit documentation professionally.
Atmospheric Monitoring
Continuous O2, LEL, CO, and H2S readings with acceptable range verification and alarm triggers
Rescue Plan
Non-entry rescue equipment, rescue team contact, and emergency procedures documented per entry
Entrant & Attendant Log
Track every person entering the space with entry/exit times and attendant assignments
Hazard Classification
Permit-required vs. non-permit space determination with hazard identification checklist
Ventilation Requirements
Mechanical ventilation setup, air monitoring intervals, and ventilation effectiveness verification
Lockout/Tagout Integration
Track energy isolation requirements for equipment within or adjacent to the confined space
Why This Template Is Different
Built by construction professionals who manage real projects.
POD vs. Generic Templates
Safety-Specific Design
Templates Are Just the Beginning
Plan of Day's AI platform turns this template into a living, intelligent document.
Before
Static template
After
AI-powered Plan of Day
How a Permit-Required Entry Runs
A permit-required confined space entry follows a fixed sequence under OSHA 1926 Subpart AA: test the atmosphere in order, complete and sign the permit, staff three defined roles, monitor and ventilate for the whole entry, and have retrieval in place before anyone goes in. Each step below maps to a field on this template.
Atmospheric Testing: The Order Matters
Test from outside the space before entry, with a calibrated direct-reading instrument, in this sequence. Sample the top, middle, and bottom because gases stratify by density, and give the instrument time to respond at each level. Entrants or their representative are entitled to observe the testing.
Oxygen
19.5% to 23.5% by volume
Test oxygen first. Most combustible gas sensors need adequate oxygen to read correctly, so an oxygen-deficient space can show a falsely low flammable reading.
Flammable gases and vapors
Below 10% of the lower flammable limit (LFL)
Test second, because fire and explosion are the fastest-acting hazard once the oxygen reading is trusted. Airborne combustible dust at or above its LFL also makes the atmosphere hazardous.
Toxic gases and vapors
Below the permissible exposure limit for each contaminant
Test last, for the contaminants the space can actually hold. Hydrogen sulfide and carbon monoxide are the usual targets in sewers, vaults, and tanks. Common alarm setpoints are 10 ppm H2S and 35 ppm CO.
Three Roles, Three Sets of Duties
Every permit entry names an authorized entrant, an attendant, and an entry supervisor. One person can hold more than one role only if trained and equipped for each, and the attendant always stays outside.
Authorized Entrant
29 CFR 1926.1208
Attendant
29 CFR 1926.1209
Entry Supervisor
29 CFR 1926.1210
What the Entry Permit Must Record
The entry supervisor signs the permit before entry, it is posted at the entry point, and it is valid only for the time needed to finish the task. Canceled permits are kept for at least one year so the program can be reviewed.
During the Entry and After
Continuous Monitoring
Under the construction standard the atmosphere is monitored continuously during entry, unless the employer can show that continuous equipment is not commercially available or that periodic monitoring is sufficient. If a reading leaves the acceptable range, entrants exit and the entry supervisor suspends or cancels the permit until the cause is found and corrected.
Ventilation
Forced-air ventilation draws from a clean source, is directed at the area where entrants are or will be working, and keeps running until everyone is out. Ventilation controls an atmospheric hazard. It does not eliminate it, which is why the permit records how entrants are warned if the blower fails.
Rescue: Non-Entry First
Each entrant wears a chest or full body harness with a retrieval line attached at the center of the back near shoulder level or above the head. The other end is secured to a mechanical device or fixed point outside the space, and a mechanical retrieval device is required for vertical spaces more than 5 feet deep. Retrieval is omitted only where it would increase the overall risk or would not help. Where entry rescue is the plan, the rescue service is evaluated in advance for response time and capability and must tell the employer when it becomes unavailable.
Permit vs. Non-Permit and Reclassification
A competent person evaluates each confined space. A hazardous atmosphere, an engulfment hazard, inwardly converging walls or a sloping floor, or any other serious hazard makes it permit-required. A permit space can be reclassified as non-permit only when it has no actual or potential atmospheric hazard and every other hazard has been eliminated. The certification is written, dated, signed, and names the space. If a hazard returns, everyone exits and the space is re-evaluated. Controlling the air with ventilation alone does not qualify a space for reclassification.
Reference summary of OSHA 29 CFR 1926 Subpart AA (construction) and 1910.146 (general industry). It does not replace your written permit space program or the text of the standard.
Frequently Asked Questions
A confined space is large enough to enter and perform work, has limited means of entry or exit, and is not designed for continuous occupancy. In construction, common confined spaces include manholes, tanks, vaults, pits, tunnels, and large-diameter pipes. OSHA 1926 Subpart AA covers construction-specific requirements.
A permit is required when the confined space contains or has the potential to contain a hazardous atmosphere, engulfment hazard, converging walls, or any other recognized serious safety or health hazard. The template includes a hazard assessment to determine permit requirements.
At minimum, you must test for oxygen (19.5-23.5%), flammable gases (below 10% LEL), and toxic gases such as carbon monoxide and hydrogen sulfide before and during entry. Those two are commonly alarmed at 35 ppm CO and 10 ppm H2S, and each contaminant should stay below its permissible exposure limit. The template provides continuous monitoring log fields for all four parameters.
Get Your Free Confined Space Entry Permit Template
Quick signup. Free download. Ready to use on your next project.
Related Safety Templates
Last updated: November 2026