Back online
Safety

Free Confined Space Entry Permit Template

Manage confined space entries with atmospheric monitoring, rescue planning, entrant/attendant logs, and OSHA 1926 Subpart AA compliance.

Share:
Browse all templates
3
Tabs
6
Features
Yes
Print-Ready
Free
Cost

What's Included

This template includes 3 organized sections ready for your project.

1

Entry Permit

2

Atmospheric Log

3

Rescue Plan

Key Features

Everything you need to manage Confined Space Entry Permit documentation professionally.

Atmospheric Monitoring

Continuous O2, LEL, CO, and H2S readings with acceptable range verification and alarm triggers

Rescue Plan

Non-entry rescue equipment, rescue team contact, and emergency procedures documented per entry

Entrant & Attendant Log

Track every person entering the space with entry/exit times and attendant assignments

Hazard Classification

Permit-required vs. non-permit space determination with hazard identification checklist

Ventilation Requirements

Mechanical ventilation setup, air monitoring intervals, and ventilation effectiveness verification

Lockout/Tagout Integration

Track energy isolation requirements for equipment within or adjacent to the confined space

Why This Template Is Different

Built by construction professionals who manage real projects.

POD vs. Generic Templates

Built for construction
Generic officePurpose-built
Auto-calculations
ManualAutomatic
Print formatting
BasicProfessional
Related document links
NoYes
AI integration
NoPlan of Day
Cost
FreeFree

Safety-Specific Design

Designed for construction project management workflows
3 organized sections covering all critical data
Print-optimized with professional formatting and page breaks
Auto-calculations reduce manual errors and save time

Templates Are Just the Beginning

Plan of Day's AI platform turns this template into a living, intelligent document.

Before

Static template

Manual data entry into spreadsheet cells
No trend tracking or historical comparison
Static document with no intelligence
Copy-paste to distribute to stakeholders
No alerts when items are overdue or at risk

After

AI-powered Plan of Day

POD reads the files you already produce
Your project metrics tracked automatically
AI agents flag overdue items, risks, and anomalies
Instant distribution to your entire team
Trend analysis and predictive insights across all projects

How a Permit-Required Entry Runs

A permit-required confined space entry follows a fixed sequence under OSHA 1926 Subpart AA: test the atmosphere in order, complete and sign the permit, staff three defined roles, monitor and ventilate for the whole entry, and have retrieval in place before anyone goes in. Each step below maps to a field on this template.

Atmospheric Testing: The Order Matters

Test from outside the space before entry, with a calibrated direct-reading instrument, in this sequence. Sample the top, middle, and bottom because gases stratify by density, and give the instrument time to respond at each level. Entrants or their representative are entitled to observe the testing.

1

Oxygen

19.5% to 23.5% by volume

Test oxygen first. Most combustible gas sensors need adequate oxygen to read correctly, so an oxygen-deficient space can show a falsely low flammable reading.

2

Flammable gases and vapors

Below 10% of the lower flammable limit (LFL)

Test second, because fire and explosion are the fastest-acting hazard once the oxygen reading is trusted. Airborne combustible dust at or above its LFL also makes the atmosphere hazardous.

3

Toxic gases and vapors

Below the permissible exposure limit for each contaminant

Test last, for the contaminants the space can actually hold. Hydrogen sulfide and carbon monoxide are the usual targets in sewers, vaults, and tanks. Common alarm setpoints are 10 ppm H2S and 35 ppm CO.

Three Roles, Three Sets of Duties

Every permit entry names an authorized entrant, an attendant, and an entry supervisor. One person can hold more than one role only if trained and equipped for each, and the attendant always stays outside.

Authorized Entrant

29 CFR 1926.1208

Knows the hazards of the space, including the signs, symptoms, and consequences of exposure
Uses the equipment listed on the permit the way it was intended
Stays in communication with the attendant for the whole entry
Alerts the attendant at the first warning sign or prohibited condition
Exits immediately when ordered, when an alarm sounds, or when a symptom appears

Attendant

29 CFR 1926.1209

Stays outside the space until relieved by another attendant
Keeps an accurate count and identity of every entrant inside
Watches conditions inside and outside the space and orders evacuation when needed
Summons rescue as soon as entrants may need help and performs non-entry rescue
Keeps unauthorized people away and takes on no task that distracts from the watch
Does not enter for rescue unless trained and equipped as a rescuer and relieved by another attendant

Entry Supervisor

29 CFR 1926.1210

Verifies that testing is complete and every procedure and piece of equipment on the permit is in place before signing
Confirms rescue services are available and the means to summon them works
Removes unauthorized people who enter or try to enter during the entry
Terminates the entry and cancels the permit when work ends or a prohibited condition arises
Verifies that acceptable entry conditions still hold whenever responsibility transfers, such as at shift change

What the Entry Permit Must Record

The entry supervisor signs the permit before entry, it is posted at the entry point, and it is valid only for the time needed to finish the task. Canceled permits are kept for at least one year so the program can be reviewed.

The permit space to be entered and the purpose of the entry
The date and the authorized duration of the permit
Authorized entrants, by name or by a roster or tracking system
Each attendant and the entry supervisor, with the supervisor's signature
The hazards of the space
The measures used to isolate the space and eliminate or control its hazards, such as lockout, purging, inerting, ventilating, and flushing
The acceptable entry conditions
Initial and periodic test results, with the tester's name or initials and the time of each test
How entrants will be alerted if the ventilation system stops working
The rescue and emergency services to call and how to summon them
The communication procedure between entrants and attendants
Required equipment: PPE, testing instruments, communications, alarms, and rescue gear
Any additional permits issued for work in the space, such as hot work

During the Entry and After

Continuous Monitoring

Under the construction standard the atmosphere is monitored continuously during entry, unless the employer can show that continuous equipment is not commercially available or that periodic monitoring is sufficient. If a reading leaves the acceptable range, entrants exit and the entry supervisor suspends or cancels the permit until the cause is found and corrected.

Ventilation

Forced-air ventilation draws from a clean source, is directed at the area where entrants are or will be working, and keeps running until everyone is out. Ventilation controls an atmospheric hazard. It does not eliminate it, which is why the permit records how entrants are warned if the blower fails.

Rescue: Non-Entry First

Each entrant wears a chest or full body harness with a retrieval line attached at the center of the back near shoulder level or above the head. The other end is secured to a mechanical device or fixed point outside the space, and a mechanical retrieval device is required for vertical spaces more than 5 feet deep. Retrieval is omitted only where it would increase the overall risk or would not help. Where entry rescue is the plan, the rescue service is evaluated in advance for response time and capability and must tell the employer when it becomes unavailable.

Permit vs. Non-Permit and Reclassification

A competent person evaluates each confined space. A hazardous atmosphere, an engulfment hazard, inwardly converging walls or a sloping floor, or any other serious hazard makes it permit-required. A permit space can be reclassified as non-permit only when it has no actual or potential atmospheric hazard and every other hazard has been eliminated. The certification is written, dated, signed, and names the space. If a hazard returns, everyone exits and the space is re-evaluated. Controlling the air with ventilation alone does not qualify a space for reclassification.

Reference summary of OSHA 29 CFR 1926 Subpart AA (construction) and 1910.146 (general industry). It does not replace your written permit space program or the text of the standard.

Frequently Asked Questions

A confined space is large enough to enter and perform work, has limited means of entry or exit, and is not designed for continuous occupancy. In construction, common confined spaces include manholes, tanks, vaults, pits, tunnels, and large-diameter pipes. OSHA 1926 Subpart AA covers construction-specific requirements.

A permit is required when the confined space contains or has the potential to contain a hazardous atmosphere, engulfment hazard, converging walls, or any other recognized serious safety or health hazard. The template includes a hazard assessment to determine permit requirements.

At minimum, you must test for oxygen (19.5-23.5%), flammable gases (below 10% LEL), and toxic gases such as carbon monoxide and hydrogen sulfide before and during entry. Those two are commonly alarmed at 35 ppm CO and 10 ppm H2S, and each contaminant should stay below its permissible exposure limit. The template provides continuous monitoring log fields for all four parameters.

Get Your Free Confined Space Entry Permit Template

Quick signup. Free download. Ready to use on your next project.

Last updated: November 2026