Battery StorageAugmentedon the Record
Batteries degrade. Augmentation adds new racks on the same PCS and interconnection to restore the nameplate and boost past it. POD puts the racks replaced, the MWh added, and the outage window on one report, built from a voice note in the field.
Augmentation is a capacity project inside a live plant, and a build template can't hold it
Every lithium battery loses usable capacity as it ages, so an operating storage site is augmented — degraded racks replaced and new ones added on the same PCS, thermal system, and interconnection, to restore the nameplate and often boost beyond it. It is a removal and an addition inside a live plant, on an outage window. A greenfield template captures none of it. POD reports the racks replaced, the MWh added, and the return to service, the day each moves.
What an augmentation day has to carry
Degraded-rack replacement
Aging cells and racks pulled and swapped for new modules, with the old ones routed to recycling. What came out, how much capacity it had lost, and where it went — inside a live storage plant.
Capacity addition
New racks added to restore the nameplate and often boost beyond it. The MWh added is the number the augmentation is justified by — logged block by block.
Reused PCS & interconnection
The power conversion, the thermal system, and the grid tie stay. POD reports against the existing base: what was reused as-is, what was retuned for the new cells, and where the interconnection stands.
Re-commissioning & capacity test
Rack integration, thermal recharge, protection re-check, and the capacity test that proves the new MWh. Each block flips from degraded to back at nameplate — and the outage window holds.
Racks stacked back to nameplate, and beyond
Each enclosure of degraded racks falls short of the nameplate line — then new racks stack up column by column, restoring the lost capacity and boosting past it, on the same PCS.
What the augmentation looks like on the dashboard
Two numbers an owner reads: the ROI on each augmentation set, and whether the work is starting on time inside the outage window.
Equipment ROI
PODStart Reliability
The augmentation POD tracks
From the first state-of-health check to the capacity test — every phase reported the day it moves.
Degradation assessment
State-of-health measured, degraded racks identified, and the augmentation sized. The project is planned around what the existing plant can keep.
Rack removal & replacement
Aging racks de-energized, pulled, and routed to recycling; new modules staged. The removal half inside a live site.
Capacity addition
New racks installed and integrated onto the reused PCS and thermal loop. MWh added, block by block.
Re-commissioning & capacity test
Protection re-checked, thermal recharged, and the capacity test run against the new nameplate. Each block returns to service within the window.
Built for the augmentation, not a greenfield form
| What gets tracked | Greenfield template | POD repower platform |
|---|---|---|
| Progress % | Plus racks replaced + MWh added + re-energized | |
| Equipment | Same PCS / thermal — reused vs retuned | |
| Test log | Capacity test proving the new nameplate MWh | |
| Degraded-rack replacement | Racks out, capacity lost, recycled | |
| Reused PCS / interconnection | As-is vs retuned for the new cells | |
| MWh capacity restored + boosted | The number the augmentation is justified by |
Free BESS augmentation template & KPI tools
Grab the free BESS augmentation daily-report template — built for state-of-health, degraded-rack removal, augmentation, reused PCS, and MWh uplift — or use POD's free KPI calculators. Excel, PDF, or HTML. No account needed.
BESS augmentation questions
Lithium batteries lose usable capacity over their life, so an operating storage site is augmented — new racks or modules added (and degraded ones replaced) to restore the nameplate and often boost beyond it, on the existing PCS, thermal system, and interconnection. It is a targeted capacity project inside a live plant, not a greenfield build, and it needs a report that tracks the racks replaced, the MWh added, and the outage window.
Put the racks replaced and the MWh added on one record
Speak the day from the yard. POD logs the degraded racks out, the new capacity in, the reused PCS, and the capacity test, and keeps the restored-and-boosted MWh in front of the owner.